Tropical Depression 12W
Passive Microwave (PMW) Intensity Information Advanced Dvorak Technique (ADT) Version 8.1.5 |
Overpass Inten Ring Ring Wind Forecast Final Target Date Time Score Meaning Pct Diam BTdiff Est Sat Lat Lon Lat Lon Lat Lon 20130817 032324 -0.0 N/A 5.5% 66.66 .04 25.0 TRMM 21.2 -124.8 21.2 -124.8 21.2 -125.0 Analysis Plot 20130817 084600 -2.9 N/A 21.9% 144.43 2.92 30.0 SSMI17 20.5 -125.5 20.5 -125.5 20.8 -125.6 Analysis Plot 20130817 105500 -1.8 N/A 11.0% 111.10 1.76 30.0 SSMI18 20.5 -125.8 20.5 -125.8 20.8 -125.7 Analysis Plot 20130817 211800 -7.1 N/A 9.6% 199.98 7.12 30.0 SSMI17 20.2 -127.0 20.2 -127.0 20.7 -127.0 Analysis Plot 20130817 232700 -5.6 N/A 4.1% 211.09 5.56 30.0 SSMI18 20.2 -127.2 20.2 -127.2 20.4 -127.3 Analysis Plot 20130818 022619 -5.1 N/A 16.4% 166.65 5.14 30.0 TRMM 20.3 -127.5 20.3 -127.5 20.8 -127.2 Analysis Plot 20130818 084449 -6.0 N/A 21.9% 55.55 5.98 30.0 SSMI15 20.3 -127.9 20.3 -127.9 20.0 -127.2 Analysis Plot 20130818 104200 -930.0 N/A N/A N/A 5.16 35.0 SSMI18 20.5 -128.1 20.5 -128.1 20.3 -128.3 Analysis Plot 20130818 185748 -930.0 N/A N/A N/A 4.05 40.0 TRMM 19.8 -127.5 19.8 -127.5 20.1 -128.0 Analysis Plot 20130818 200338 -0.0 N/A N/A N/A 0.00 40.0 SSMI15 19.9 -127.5 19.9 -127.5 19.4 -127.3 Analysis Plot 20130818 210600 -31.8 N/A 90.4% 55.55 16.77 40.0 SSMI17 19.9 -127.5 19.9 -127.5 19.4 -127.6 Analysis Plot 20130818 231600 -10.0 N/A 74.0% 99.99 10.03 40.0 SSMI18 20.0 -127.4 20.0 -127.4 19.1 -127.7 Analysis Plot 20130819 013130 -930.0 N/A N/A N/A 6.91 45.0 TRMM 19.5 -127.7 19.5 -127.7 19.8 -128.3 Analysis Plot 20130819 075010 -11.3 N/A 46.6% 99.99 11.33 45.0 SSMI15 19.9 -127.9 19.9 -127.9 19.8 -128.0 Analysis Plot 20130819 084800 -930.0 N/A N/A N/A 5.72 50.0 SSMI16 20.1 -128.1 20.1 -128.1 20.4 -128.1 Analysis Plot 20130819 193009 0.4 N/A 11.0% 133.32 .40 55.0 SSMI15 20.7 -129.0 20.7 -129.0 21.1 -128.1 Analysis Plot 20130820 083600 0.2 N/A 9.6% 144.43 .18 55.0 SSMI16 23.4 -127.2 23.4 -127.2 23.0 -126.8 Analysis Plot 20130820 184412 11.3 N/A 37.0% 166.65 11.26 60.0 TRMM 24.5 -125.8 24.7 -125.9 24.7 -125.9 Analysis Plot 20130820 210700 3.7 N/A 31.5% 144.43 3.68 60.0 SSMI16 24.7 -125.1 24.7 -125.1 24.8 -124.9 Analysis Plot 20130820 221900 5.5 N/A 60.3% 88.88 5.51 60.0 SSMI17 24.8 -124.8 24.8 -124.8 24.9 -124.8 Analysis Plot 20130821 003000 37.9 >65 kts 100.0% 77.77 22.91 65.0 SSMI18 25.3 -124.2 25.3 -124.4 25.3 -124.4 Analysis Plot 20130821 011615 -930.0 N/A N/A N/A 14.85 65.0 TRMM 25.2 -124.2 25.4 -123.8 25.4 -123.8 Analysis Plot 20130821 082500 12.3 N/A 69.9% 55.55 12.31 65.0 SSMI16 25.8 -122.4 25.7 -122.2 25.7 -122.2 Analysis Plot 20130821 174729 -0.0 N/A N/A N/A 0.00 70.0 TRMM 26.1 -119.9 25.9 -119.6 25.9 -119.6 Analysis Plot 20130821 220600 -930.0 N/A N/A N/A 6.51 75.0 SSMI17 25.9 -118.6 25.9 -118.6 26.7 -118.3 Analysis Plot 20130822 001832 -0.0 N/A N/A N/A 0.00 75.0 TRMM 25.9 -118.3 25.9 -118.3 26.1 -118.0 Analysis Plot 20130822 092400 -0.0 N/A N/A N/A 0.00 75.0 SSMI17 26.3 -116.2 26.3 -116.2 27.0 -116.4 Analysis Plot 20130822 113600 -930.0 N/A N/A N/A 6.91 75.0 SSMI18 26.3 -115.7 26.3 -115.7 27.5 -116.1 Analysis Plot |
Legend: - Date/Time are determined from PMW imagery at Forecast (initial guess) Lat/Lon position. - Positive/Negative Latitude = North/South Hemisphere; Longitude = Western/Eastern Hemisphere. - "Ring Diam" value indicates the estimated surface eyewall diameter in km (the MI eyewall edge diameter minus 10 km). - "Ring Pct" is the percentage of the "ring" (eyewall inner boundary) that is 1) colder than the "hot spot" (warmest eye pixel) in the eye by 20K, or 2) the percentage that is a) colder than 232K and b) colder than the "hot spot" by 10K, whichever is greater. - Values are red if Ring % <= 65, yellow/brown if Ring % <= 85 and green if Ring % > 85. - "Tb diff" is the difference between the "hot spot" (warmest eye pixel) and the warmest pixel on the eyewall. - Intensity score are listed as negative, and not used, when the JTWC or NHC estimated Vmax is <55 kts in order to rule out weak but highly symmetric TCs. - Error messages in intensity scores: -920 is used when the hottest pixel in the eye is <200K, to prevent false positives; -930 means <85% of eyewall has observations/data. |